L200

Model Details
- Softwood Drying Capacity 1,500-2,500BF
- Hardwood Drying Capacity 4,000BF
- Water Removal / Day 250 Lbs.
- Voltage Requirements 220V
Nyle’s L200 models allow you to dry your lumber down to 6-8% moisture content for pennies per board foot. These compact, high-performance dehumidification systems will dry between 1,500 and 4,000 board feet of lumber.
Available in two options, the L200S includes two circulating fans, a kiln control, and a powered vent kit. While the L200M adds upgraded controls with moisture probes.
L 200 Dehumidification System
- Dry your lumber down to 6 – 8% moisture content for pennies per board foot.
- Operates between 70°F – 120°F.
- Set pitch or sterilize with the included auxiliary heater.
- Additional fans available
Quality
The L200 is built to last. Extra heavy-duty coils are coated to Nyle specifications to prevent them from corrosion. Over four decades of experience have shown us how to achieve the longest life. Our fans provide circulation to ensure even drying. The chassis is 100% corrosion-resistant aluminum, and our remote controller has been proven in thousands of applications.
Service
Everything in a Nyle dehumidification unit can be replaced. This is not a disposable product. We know that people run even our smaller units well into their second decade, and we build them to last. In addition, we offer technical assistance over the phone. The people who build our machines handle service calls, so you get the straight talk when needed.
There are two control systems available with the L200
L200S Standard Control System.
The traditional L200 has a precise controller which requires just a few minutes of daily monitoring. Controls include a thermostat with a remote sensor and compressor timer. This system has been proven in thousands of installations since 1984. The temperature control turns the supplemental heat on and off as needed. It displays both the setpoint and the actual kiln temperature. The humidity is managed by using a wet-bulb sensor and controls the operation of the compressor. This is a simple, reliable, time-tested system.
L200M Temperature and Wet Bulb with Wood Moisture Probes.
The temperature and humidity are controlled by the wet bulb and dry bulb sensors. The temperature control turns the supplemental heat on and off as needed. Wet bulb is the most accurate way to measure humidity, and it controls the operation of the compressor. In addition, this controller provides four digital readouts of wood moisture content. The system can be set to shut down when all four probes read the target moisture content.